PPS supplier: heat, chemicals and flame rating in one resin
Glass-filled polyphenylene sulfide holds its shape past 200°C, resists fuels, coolants and solvents, and most grades are rated UL 94 V-0 without flame-retardant additives, at the thickness on each grade's yellow card.
One gaylord to a truckload · Every prime lot from our suppliers ships with a COA
Request a QuoteShop-floor numbers
- Drying
- 120 to 163°C / 248 to 325°F, 2 to 4 h
- Melt temp
- 300–340°C / 572–644°F
- Mold temp
- 135–160°C / 275–320°F
- Shrinkage
- 1.2–1.4% along, 1.5–1.9% across, unfilled
- Heat (HDT)
- ~105°C unfilled, ~260°C glass-filled
- Grades
- Glass-filled (30% and 40%) · Glass + mineral filled (high-fill, low-warp) · Unfilled linear and branched PPS
Typical values; confirm against the grade’s data sheet. One gaylord to a truckload · Supplier COA on every prime lot · Ships to the U.S. and Canada.
The short answer
PPS is the value pick for hot, chemical-wetted parts: glass-filled grades hold shape above 200°C, absorb almost no water and most are rated UL 94 V-0 without added flame retardant (check the thickness on the grade's yellow card). Choose it before PEEK when the part does not see heavy impact or fatigue. The two things that go wrong are flash, because the melt is very thin, and parts that change size later because the mold ran in the 88–127°C band.
Grades we source
Tap a grade to add it to your quote request.
About PPS
PPS is a semi-crystalline high-temperature resin that sits between engineering nylons and PEEK. It is dimensionally stable, absorbs almost no moisture, resists nearly every fuel, coolant and solvent it meets in service, though strong oxidizing acids such as concentrated nitric acid attack it, and is inherently flame retardant. Unfilled PPS is brittle, so most parts run a glass-filled or glass-and-mineral grade. It needs a hot mold (135–160°C) to crystallize fully and reach its rated heat performance.
Common applications
- Under-hood coolant and thermostat housings
- Water pump impellers and fuel-system components
- Electrical connectors, bobbins and sockets
- Pump, valve and flow-meter parts for chemical service
- Appliance and HVAC components near heat
- Metal replacement where corrosion is the problem
Typical properties
| Impact strength | Fair (notch-sensitive) |
|---|---|
| Heat (HDT) | ~105°C unfilled, ~260°C glass-filled |
| Flame rating | Inherently UL 94 V-0 |
| Clarity | Opaque |
| Chemical resistance | Outstanding |
| Relative cost | High |
How PPS compares
| PPS | PPA | PEEK | |
|---|---|---|---|
| Continuous use temperature | ~200–220°C | ~130–160°C | ~240–260°C |
| Chemical resistance | Outstanding | Very good | Outstanding |
| Strength and stiffness | High with glass; brittle unfilled | High; tougher than PPS | Very high |
| Processing | Injection; needs a hot mold | Injection; dry first, hot mold | Injection and extrusion; very hot melt |
| Relative cost | High | High | Very high |
Property ranges are general guidance and vary by grade and supplier; a polymer chemist reviews the spec against the data sheet and COA.
Full data sheet values: PPS GF40 properties
Which grade to ask for
Almost every molded PPS part uses a filled grade; the filler decides cost, warp and toughness.
| Grade type | Use it for | Watch out for |
|---|---|---|
| 40% glass-filled | Pump housings and impellers, fuel and coolant parts, sockets | Low elongation, so snap fits need care; cross-flow shrinkage is about 2 to 4 times the flow-direction value |
| Glass + mineral (around 65% total) | Flat, low-warp electrical and appliance parts | More brittle and heavier than GF40, with lower strength |
| Hydrolysis-rated glass-filled | Coolant and hot-water parts | Standard glass-filled PPS can lose a meaningful share of strength after long hot-water exposure |
| Impact-modified | Parts with clips, press fits or some impact | Gives up some stiffness and heat resistance; check the grade sheet |
| Carbon-filled and conductive | Stiff, light parts and static-dissipative parts | Conductive, so not for insulators |
| PTFE-lubricated | Bushings, wear strips, valve parts | PTFE content matters if your program restricts fluoropolymers |
| Low-flash grades | Thin, tight tools and connectors | Still need tight parting lines; compare flow on the sheet |
Typical starting points. Grades vary, so confirm on the data sheet for the exact grade.
Processing notes
- Drying. The resin itself barely absorbs water, but mineral fillers do. Dry at 120 to 163°C / 248 to 325°F for 2 to 4 h to 0.02%. Published drying temperatures differ between suppliers, so follow your grade’s sheet. See the drying chart for other resins.
- Melt temperature. 300–340°C / 572–644°F. Do not exceed 340°C / 644°F.
- Mold temperature. 135–160°C / 275–320°F with oil or electric heating. Colder molds leave a partly amorphous skin that can keep crystallizing in service, so parts can change size later.
- Shrinkage. Unfilled about 1.2–1.4% along flow and 1.5–1.9% across. With 40% glass about 0.2–0.3% along flow and 0.5–0.8% across (Fortron 1140L4 0.3 / 0.6%), so gate location drives warp.
- Regrind. Often up to 25% of the same grade. The melt is stable, but glass fibers shorten with each pass and strength and impact drop with them.
- Most common defect. Flash. PPS melt is very thin and runs into gaps that polycarbonate or ABS would not enter. Keep parting lines tight, size vents for PPS, and do not run above the melt range. Vent deposits also build up over a run, so clean vents on a schedule.
What to put on the purchase order
- Fill type and percentage. GF40, glass + mineral, carbon or lubricated. For unfilled grades, say linear or branched; linear grades are tougher.
- Melt flow and test condition. Copy both from the data sheet so the COA value can be compared.
- Service conditions. For coolant or hot water, ask for a hydrolysis-rated grade and give the automaker or customer material spec if there is one.
- Flame and electrical documents. UL recognition is grade-specific and color-specific. Check the grade’s listing on UL Product iQ for V-0 at your wall thickness, RTI and CTI.
- Color. Natural (tan) or black. Black is the most common for molded parts.
- Food contact. Ask for the producer’s FDA letter for the exact grade.
- COA values to check. Melt flow and filler content (ash) against the data sheet range.
When to consider something else
- If the part sees impact, high strain or fatigue, or runs above about 220°C, look at PEEK.
- If you need more toughness for structural parts at lower continuous heat, see PPA vs. PA66.
- If the part runs below about 150°C and cost is the driver, look at glass-filled nylon.
- If you need transparency or aircraft-interior flame and smoke data, look at PEI.
Named grades with their own page
Typical data, close alternatives to qualify and buying notes for common named grades in this family: Ryton R-4 · Fortron 1140L4
Common questions
What mold temperature does PPS need?
About 135–160°C (275–320°F), with oil or electric heating. Colder molds leave a partly amorphous skin that can keep crystallizing in service, so parts can shrink or warp later in service.
Does PPS need to be dried?
Usually yes, mainly because fillers and surface moisture cause problems, even though the resin absorbs almost no water. Dry at 120 to 163°C (248 to 325°F) for 2 to 4 hours, following your grade’s sheet.
Is PPS flame retardant?
Yes. Most PPS grades meet UL 94 V-0 without flame-retardant additives. UL recognition is grade-specific and color-specific and applies at a stated thickness, so check the grade’s listing on UL Product iQ.
Why does PPS flash so easily?
PPS has a very low-viscosity melt, so it runs into small gaps at parting lines, vents and ejector pins. Tight tooling, vents sized for PPS, staying within the melt range and low-flash grades all help.
Related pages (12)
Talk to a polymer chemist
Have a grade on a print, a bag label, or just a part you need to make? Send what you have.
- Send the grade, a callout or a photo of the bag label.
- We check it, and suggest a matched alternative if it is hard to get.
- We aim to quote within one to three business days, from one gaylord to a railcar.
Tell us the PPS grade you run now
A polymer chemist reviews every request, then matches your grade or finds a matched alternative and prices it.
What to send for an accurate quote
- The grade name, from any supplier, or a data sheet
- Color (natural, black or a custom match)
- Fill type and percentage, if any
- Melt flow, if you know it
- Quantity for this order and what you use in a year
- Ship-to ZIP or postal code